Secured Trading Service

High Temperature Dissolved Oxygen Sensor for Fermentation

Shanghai Boqu Instrument Co., Ltd.
  • Audited Supplier
  • 13 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • High Temperature Resistance: Specially designed to resist 130 degrees steam sterilization without deformation.
  • Wide Application Scope: Suitable for microbial culture reactors, environmental monitoring, wastewater treatment, and aquaculture.
  • Fast Response Time: Achieves 95% response in about 60 seconds for efficient online measurement.
  • High Stability: Response current drift is less than 3% per week under constant temperature and pressure.
  • Low Flow Requirement: Requires liquid mixing flow of 3% or less for accurate electrode response.
  • Multiple Diameter Options: Available in 12 mm, 19 mm, and 25 mm electrode diameters to fit various reactors.
  • OEM/ODM Services: Manufacturer offers both OEM and ODM services for customized production needs.
  • CE Certified: Product meets CE certification standards for safety and quality assurance.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of High Temperature Dissolved Oxygen Sensor for Fermentation

High Temperature Dissolved Oxygen Sensor for Fermentation
High Temperature Dissolved Oxygen Sensor for Fermentation pictures & photos
High Temperature Dissolved Oxygen Sensor for Fermentation
High Temperature Dissolved Oxygen Sensor for Fermentation pictures & photos
High Temperature Dissolved Oxygen Sensor for Fermentation
High Temperature Dissolved Oxygen Sensor for Fermentation pictures & photos
High Temperature Dissolved Oxygen Sensor for Fermentation
High Temperature Dissolved Oxygen Sensor for Fermentation pictures & photos
High Temperature Dissolved Oxygen Sensor for Fermentation
High Temperature Dissolved Oxygen Sensor for Fermentation pictures & photos
High Temperature Dissolved Oxygen Sensor for Fermentation
High Temperature Dissolved Oxygen Sensor for Fermentation pictures & photos
High Temperature Dissolved Oxygen Sensor for Fermentation
  • High Temperature Dissolved Oxygen Sensor for Fermentation
  • High Temperature Dissolved Oxygen Sensor for Fermentation
    High Temperature Dissolved Oxygen Sensor for Fermentation
  • High Temperature Dissolved Oxygen Sensor for Fermentation
    High Temperature Dissolved Oxygen Sensor for Fermentation
  • High Temperature Dissolved Oxygen Sensor for Fermentation
    High Temperature Dissolved Oxygen Sensor for Fermentation
  • High Temperature Dissolved Oxygen Sensor for Fermentation
    High Temperature Dissolved Oxygen Sensor for Fermentation
  • High Temperature Dissolved Oxygen Sensor for Fermentation
    High Temperature Dissolved Oxygen Sensor for Fermentation
  • High Temperature Dissolved Oxygen Sensor for Fermentation
    High Temperature Dissolved Oxygen Sensor for Fermentation

Find Similar Products

Product Description

DOG-208FA High Temperature Dissolved Oxygen Sensor

Technical Indexes:              

DOG-208FA electrode, which is specially designed to be resistant to 130 degrees steam sterilization, the pressure auto-balance high temperature dissolved oxygen electrode, for liquids or gases dissolved oxygen measurement, the electrode is most suitable for small microbial culture reactor dissolved oxygen levels on line. Can also be used for environmental monitoring, wastewater treatment and aquaculture on-line measurement dissolved oxygen levels.

Dissolved oxygen electrode characteristics
1DOG-208FA high temperature fermentation dissolved oxygen
electrode applicable for Polarographic Principle
2.With imported breathable membrane heads
3.Steel gauze electrode membrane and silicone rubber
4.Endure high temperature, No deformation characteristics


Technical indexes
1.Electrode body material: stainless steel
2.Permeable membrane: fluorine plastic,
silicone, stainless steel wire mesh composite membrane.
3.Cathode: platinum wire
4.Anode: silver
5.Electrodes built-in temperature sensor: PT1000
6.The response current in the air: About 60nA
7.The response current in a nitrogen atmosphere: less than
one percent response current of response in air.
8.Electrode response time: about 60 seconds (up 95% response)
9.Electrode Response Stability: a constant oxygen partial pressure
at a constant temperature environment, response current drift less
than 3% per week
Liquid mixing flow to the electrode response: 3% or less (in water at
room temperature)
Electrode Response Temperature Coefficient: 3% (greenhouse)
Insert the electrode diameter: 12 mm, 19 mm, 25 mm optional
 
 


High Temperature Dissolved Oxygen Sensor for Fermentation

High Temperature Dissolved Oxygen Sensor for FermentationHigh Temperature Dissolved Oxygen Sensor for FermentationHigh Temperature Dissolved Oxygen Sensor for FermentationHigh Temperature Dissolved Oxygen Sensor for FermentationHigh Temperature Dissolved Oxygen Sensor for FermentationHigh Temperature Dissolved Oxygen Sensor for FermentationHigh Temperature Dissolved Oxygen Sensor for Fermentation
 
 

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2142034". Items marked "verified" are certified.

Watch Video
Watch Video
Shanghai Boqu Instrument Co., Ltd.
Shanghai Boqu Instrument Co., Ltd.
Shanghai Boqu Instrument Co., Ltd.
Shanghai Boqu Instrument Co., Ltd.
Shanghai Boqu Instrument Co., Ltd.
Shanghai Boqu Instrument Co., Ltd.
Shanghai Boqu Instrument Co., Ltd.
Shanghai Boqu Instrument Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory
Address
No. 118 Xiuyan Road, Pudong District, Shanghai, China
verified Plant Area
1368 square meters
verified Number of Employees
111
verified Registered Capital
10,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port

Our Production Capability & Technical Expertise

verified Main Products
PH, ORP, Conductivity, Dissolved Oxygen, Residual Chlorine, Turbidity, TSS, Ion Ammonia Nitrogen, Nitrate Nitrogen, Blue-Green Algae, Chlorophyll A, COD Analyzer & Sensor (electrode)
verified Production Machines
Assembly Line
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
10 people
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2007-05-23
Export Year
2014-01-06
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia, Domestic
verified Number of Foreign Trading Staff
12
verified Overseas Agent/Branch
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE

FAQ

What is the maximum temperature resistance?
The sensor is designed to resist 130 degrees steam sterilization without deformation.
What are the available electrode diameters?
The sensor is available in 12 mm, 19 mm, and 25 mm diameters.
How long does it take to respond?
The electrode response time is about 60 seconds to reach 95% response.
Is the product suitable for wastewater treatment?
Yes, it is suitable for environmental monitoring, wastewater treatment, and aquaculture.
What is the response current stability?
The response current drift is less than 3% per week in a constant environment.
Does the manufacturer offer customization?
Yes, OEM and ODM services are available for this product.
What is the minimum liquid flow required?
The liquid mixing flow to the electrode response must be 3% or less.
What certifications does the product have?
The product holds CE certification.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now