Industrial Dissolved Oxygen Sensor High Quality

Measuring Range: 0-100ug/L 0-20mg/L
Polarization Voltage: 0.7V
Electrode Material: 316L Stainless Steel
Temperature Compensation Resistor: 2.252K 22K Ptl0
Sensor Life: >3 Years
Cable Length: 5m (Double Shielded)
Samples:
US$ 570/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Dog-208F
Detection Lower Limit
0.1ug/L(Ppb)(20ºC)
Measurement Upper Limit
20mg/L(Ppm)
Response Time
≤3min(90%, 20ºC)
Polarization Time
>8h
Transport Package
Carton Box
Specification
PT1000
Trademark
BOQU
Origin
China(Mainland)
HS Code
9027809900
Production Capacity
300 Sets/Week

Product Description

DOG-208F Industrial Dissolved Oxygen Sensor

Features
DOG-208F Dissolved Oxygen Electrode applicable for Polarography Principle
With platinum (Pt) as cathode and Ag / AgCl as anode
The electrolyte is 0.1 M potassium chloride (KCI).
The silicone rubber permeable membrane imported from U.S. serves as the permeable
membrane.
It has silicone rubber and steel gauze.
It is featured by collision resistance, corrosion resistance, high.temperature resistance, shape
retention and other performances

Technical Indexes
Measuring range: 0-100ug/L 0-20mg/L
Electrode material: 316L stainless steel
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc
Sensor life: >3 years
Cable length: 5m (double shielded)
Detection lower Limit: 0.1ug/L(ppb)(20ºC)
Measurement upper limit: 20mg/l(ppm)
Response time: ≤3min(90%, 20ºC)
Polarization time: >8h
Minimum flow rate: 5cm/s; 515 L/h
Drift: <3%/month
Measurement error: <±1 ppb
Air current: 50-80nA   Note: Maximum current 20-25 uA
Polarization voltage: 0.7V
Zero Oxygen: <5ppb(60min)
Calibration intervals: >60 days
Measured water temperature:0~60ºC


Scope of application
Applied to thermal power plants, power plant desalted water,.
boiler feed water etc places of trace oxygen content.
Industrial Dissolved Oxygen Sensor High QualityIndustrial Dissolved Oxygen Sensor High QualityIndustrial Dissolved Oxygen Sensor High QualityIndustrial Dissolved Oxygen Sensor High QualityIndustrial Dissolved Oxygen Sensor High QualityIndustrial Dissolved Oxygen Sensor High QualityIndustrial Dissolved Oxygen Sensor High QualityIndustrial Dissolved Oxygen Sensor High Quality