• Online Dissolved Oxygen Sensor/Analyzer
  • Online Dissolved Oxygen Sensor/Analyzer
  • Online Dissolved Oxygen Sensor/Analyzer
  • Online Dissolved Oxygen Sensor/Analyzer
  • Online Dissolved Oxygen Sensor/Analyzer
  • Online Dissolved Oxygen Sensor/Analyzer

Online Dissolved Oxygen Sensor/Analyzer

Measuring Range: 0-100ug/L 0-20mg/L
Electrode Material: 316L Stainless Steel
Temperature Compensation Resistor: 2.252K 22K Ptl0
Sensor Life: >3 Years
Cable Length: 5m (Double Shielded)
Detection Lower Limit: 0.1ug/L(Ppb)(20ºC)
Samples:
US$ 560/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
DOG-208FA
Measurement Upper Limit
20mg/L(Ppm)
Response Time
≤3min(90%, 20ºC)
Polarization Time
>8h
Minimum Flow Rate
5cm/S; 515 L/H
Transport Package
Carton Box
Specification
Stainless steel
Trademark
BOQU
Origin
China(Mainland)
HS Code
9027809900
Production Capacity
300PCS/Week

Product Description

   
DOG-208F Industrial Dissolved Oxygen Sensor

Features
DOG-208F Dissolved Oxygen Electrode applicable for Polarography Principle
With platinum (Pt) as cathode and Ag / AgCl as anode
The electrolyte is 0.1 M potassium chloride (KCI).
The silicone rubber permeable membrane imported from U.S. serves as the permeable
membrane.
It has silicone rubber and steel gauze.
It is featured by collision resistance, corrosion resistance, high.temperature resistance, shape
retention and other performances

Technical Indexes
Measuring range: 0-100ug/L 0-20mg/L
Electrode material: 316L stainless steel
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc
Sensor life: >3 years
Cable length: 5m (double shielded)
Detection lower Limit: 0.1ug/L(ppb)(20ºC)
Measurement upper limit: 20mg/l(ppm)
Response time: ≤3min(90%, 20ºC)
Polarization time: >8h
Minimum flow rate: 5cm/s; 515 L/h
Drift: <3%/month
Measurement error: <±1 ppb
Air current: 50-80nA   Note: Maximum current 20-25 uA
Polarization voltage: 0.7V
Zero Oxygen: <5ppb(60min)
Calibration intervals: >60 days
Measured water temperature:0~60ºC


Scope of application
Applied to thermal power plants, power plant desalted water,.
boiler feed water etc places of trace oxygen content.
Online Dissolved Oxygen Sensor/Analyzer
Online Dissolved Oxygen Sensor/AnalyzerOnline Dissolved Oxygen Sensor/AnalyzerOnline Dissolved Oxygen Sensor/AnalyzerOnline Dissolved Oxygen Sensor/AnalyzerOnline Dissolved Oxygen Sensor/AnalyzerOnline Dissolved Oxygen Sensor/AnalyzerOnline Dissolved Oxygen Sensor/Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now