Principle
In pH measurement, the used electrode is also known as the primary battery. The primary battery is a system,
whose role is to transfer chemical energy into electrical energy. The voltage of the battery is called the electromotive
force (EMF). This electromotive force (EMF) is composed of two half-batteries. One half-battery is called the
measuring electrode, and its potential is related to the specific ion activity; The other half-battery is the reference
battery, often called the reference electrode, which is generally interlinked with the measurement solution, and
connected to the measuring instrument.
Description
Model No.: PH8022 |
Measuring range: 0-14pH |
Temperature range:0-85ºC |
Compressive strength:0.6MPa |
Slope: ≥96% |
Material: PPS/PC |
Zero point potential: E0=7PH±0.3 |
Internal impedance: MΩ(25ºC) ≤250 MΩ |
Profile: 3-in-1Electrode (Integrating the temperature compensation and the solution grounding) |
Installation size: Upper and Lower 3/4NPT Pipe Thread |
Connection: Low-noise cable goes out directly. |
Features
1. It adopts the world-class solid dielectric and a large area of PCE liquid for junction, difficult to block and easy maintenance
2. Long-distance reference diffusion channel greatly extends the service life of electrodes in the harsh environment
3. A new design of glass bulb increases the bulb area, prevent bubble formation interference within the buffer, makes the measurement more reliable.
4. It adopts PPS/PC casing and the upper and lower 3/4NPT pipe thread, so it is easy for installation and there is no need of
the jacket, thus saving the installation cost.
5. The electrode adopts the high-quality low-noise cable, which makes the signal output length less than 20 meters free of interference.
6. There is no need for additional dielectric and there is a little amount of maintenance.
7. High measurement accuracy, fast echoing and good repeatability.
8. Reference electrode with silver ions AG/AgCL
9. Proper operation shall make service life longer.
10. It can be installed in the reaction tank or pipe laterally or vertically.
11. The electrode can be replaced by a similar electrode made by any other country.
FAQ
Q: Are you trading company or manufacturer ?
A: We are factory.
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock,
it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A: We cann offer the sample. it's extra
Q: What is your terms of payment ?
A: 100% T/T in advance ,balance before shippment.