Intelligent: This industrial PH meter adopts high-precision AD conversion and single chip microcomputer |
processing technologies and can be used for the measurement of the PH values and temperature, automatic |
temperature compensation and self-checking. |
Reliability: All the components are arranged on one circuit board. No complicated functional switch, adjusting |
knob or potentiometer arranged on this instrument. |
Double high impedance input: The latest components are adopted; The impedance of the double high impedance |
input can reach as high as l012Ω. It has strong interference immunity. |
Solution grounding: This can eliminate all the disturbance of the ground circuit. |
Isolated current output: Optoelectronic isolating technology is adopted. This meter has strong interference |
immunity and the capacity of long-distance transmission. |
Communication interface: it can be easily connected to a computer to perform monitoring and communication. |
Automatic temperature compensation: It performs automatic temperature compensation when the temperature is |
within the range of 0~99.9ºC. |
Water proof and dust-proof design: Its protection grade is IP54. It is applicable for outdoor use. |
Display, menu and notepad: It adopts menu operation, which is like that in a computer. It can be easily |
operated only according to the prompts and without guidance of the operation manual. |
Multi-parameter display: The PH values, input mV values (or output current values), temperature, time and status |
can be displayed on the screen at the same time. |
1. Measuring range: PH value: 0~14.00pH; division value: 0.01pH |
Electric potential value: ±1999.9mV; division value: 0.1mV |
Temperature: 0~99.9ºC; division value: 0.1ºC |
2. Range for automatic temperature compensation: 0~99.9ºC, with 25ºC as the reference temperature, (0~150ºC for Option) |
3. Water sample tested: 0~99.9ºC,0.6Mpa |
4. Automatic temperature compensation error of the electronic unit: ±0 03pH |
5. Repeatability error of the electronic unit: ±0.02pH |
6. Stability: ±0.02pH/24h |
7. Input impedance: ≥1x1012Ω |
8. Clock accuracy: ±1 minute/month |
9. Isolated current output: 0~10mA(load <1 5kΩ), 4~20mA(load <750Ω) |
10. Output current error: ≤±l%FS |
11. The data storage capacity: 1 month (1 point/5 minutes) |
12. High and low alarm relays: AC 220V, 3A |
13. Communication interface: RS485 or 232 (optional) |
14. Power supply: AC 220V±22V, 50Hz±1Hz, 24VDC(optional) |
15. Protection grade: IP54, Alluminium shell for outdoor use |
16. Overall dimension: 146 (length) x 146 (width) x 150 (depth) mm; |
dimension of the hole: 138 x 138mm |
17. Weight: 1.5kg |
18. Working conditions: ambient temperature: 0~60ºC; relative humidity <85% |
19. It can be equipped with a 3-in-1 or 2-in-1 electrode. |