Laboratory Sodium Meter Factory Supply Laboratory Meter

Product Details
Customization: Available
After-sales Service: Provided
Warranty: Provided
Still deciding? Get samples of US$ 250/Piece
Request Sample
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
111
Year of Establishment
2007-05-23
  • Laboratory Sodium Meter Factory Supply Laboratory Meter
  • Laboratory Sodium Meter Factory Supply Laboratory Meter
  • Laboratory Sodium Meter Factory Supply Laboratory Meter
  • Laboratory Sodium Meter Factory Supply Laboratory Meter
  • Laboratory Sodium Meter Factory Supply Laboratory Meter
  • Laboratory Sodium Meter Factory Supply Laboratory Meter
Find Similar Products

Basic Info.

Model NO.
DWS-51A
Pna Value
0.00 Pna~8.00 Pna
Na+ Concentration
0.02 Ug/L~23G/L
Mv Value
-1000~ +1000 Mv. 0~99.9c
Resolution
0.1 Ug/L; 0 .1 Mv, 0.1c
Communication Interface
RS232
Electronic Unit Stability
+/- 0.02pna/3h
Power Supply
AC 220V +/- 22V, 50Hz +/- 1Hz
Power-Down Memory
> 5 Years
Detection Lower Limit
0 .2 Ug/L (8pna)
Transport Package
Carton
Trademark
BOQU
Origin
Shanghai
HS Code
9027809900
Production Capacity
500pieces/Week

Product Description

               DWS-51A Laboratory Sodium Meter

Features
Double-row digital tube: To display μg/L, pNa/mV and temperature simultaneously.
Computer-based: Adopts high-performance CPU chip, high-precision AD conversion technology 
to complete multi-parameter measurement and temperature compensation, with high precision and
good repeatability
High sensitivity: In the static water sample, it can detect 0.2ppb (8pNa)
Lasting stability: There is a very stable reading.

Laboratory Sodium Meter Factory Supply Laboratory Meter


Technical Indexes
1.Display: Double-row digital tubes display displays Sodium ion concentration and temperature simultaneously.
2.Measuring range: 0.2 ug/L~23000mg/L
              0.00 PNa~8.00 PNa.
              -1000~ +1000 mV. 0~99.9ºC
3.Resolution: 0.1 ug/L; 0 .1 mV, 0.1ºC
4.Repeatabilityreading ± 2.5%
5.Accuracy: reading ± 2.5%, ±0 .2 mV, ±0.3ºC
6.Continuous stability time: >100 seconds
7.Detection lower limit: 0 .2 ug/L (8pNa)
8.Input impedance: >1012Ω
9.Temperature compensation range: automatic/manual 0 ~ 99.9 ºC,
10.Response speed: 32 seconds (25ºC) or 50 seconds (15ºC)
11.Communication interface: RS232 
12.Power supply: AC 220V ± 22V, 50Hz ± 1Hz
13.Working conditions: ambient temperature: 0-60ºC;  relative humidity <≤90
14.Power-down memory: > 5 years
15.Calibration mode: One-point calibration, two-point calibration
Standard configuration
One secondary meter; one power supply; one reference electrode, one measuring electrode, one temperature
electrode; one set of electrode support

DWS-51A is an intelligent laboratory Sodium meter. It is equipped with the dedicated laboratory PPb sodium ion measurement electrode and the reference electrode,
with the static measurement performance in the beaker greatly improved, compares with the traditional sodium meters. As long as the user pays attention to the electrode cleaning,
the satisfactory result can be achieved. It can be widely used for continuous monitoring of sodium ions of the solutions in thermal power plants, chemical fertilizer, metallurgy,
environment protection, pharmaceutical industry, biochemical industry, foodstuff and running water.


FAQ
Q: Are you trading company or manufacturer ?
A: We are factory.

Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock,
it is according to quantity.

Q: Do you provide samples ? is it free or extra ?
A: We can offer the sample, it is extra


Q: What is your terms of payment ?
A: 100% T/T in advance ,balance before shipment.

If you have another question, pls feel free to contact us as below:
Contact: Jori Liu
 
Mobile: +86 17507082182
 Laboratory Sodium Meter Factory Supply Laboratory MeterLaboratory Sodium Meter Factory Supply Laboratory MeterLaboratory Sodium Meter Factory Supply Laboratory MeterLaboratory Sodium Meter Factory Supply Laboratory MeterLaboratory Sodium Meter Factory Supply Laboratory MeterLaboratory Sodium Meter Factory Supply Laboratory MeterLaboratory Sodium Meter Factory Supply Laboratory Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier