• Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode
  • Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode
  • Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode
  • Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode
  • Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode
  • Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode

Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode

Measuring Range: 0-100ug/L;0-20mg/L
Temperature Range: 0-60degree
Accuracy: +/- 1ppb
Temperature Compensation: PT100/PT1000//22K/2.252K/etc.
Electrolyte: Kcl
Housing Material: 316L Stainless Steel
Samples:
US$ 600/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
DOG-208F
Polarization Voltage
0.7V
Transport Package
Carton
Trademark
BOQU
Origin
Shanghai
HS Code
9027809900
Production Capacity
500pieces/Week

Product Description

     DOG-208F Industrial Pure Water Dissolved Oxygen Electrode

Features
DOG-208F Dissolved Oxygen Electrode  applicable  for 
Polarography Principle
With platinum (Pt) as cathode and Ag / AgCl as anode
The electrolyte is 0.1 M potassium chloride (KCI).
The silicone rubber permeable membrane imported from U.S. serves 
as the permeable membrane.
It has silicone rubber and steel gauze.
It is featured by collision resistance, corrosion resistance, high.
temperature resistance, shape retention and other performances

Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode

Technical Indexes
Measuring range: 0-100ug/L 0-20mg/L
Electrode material: 316L stainless steel
Temperature compensation resistor: 2.252K 22K Ptl00 Ptl000 etc
Sensor life: >3 years
Cable length: 5m (double shielded)
Detection lower Limit: 0.1ug/L(ppb)(20ºC)
Measurement upper limit: 20mg/l(ppm)
Response time: ≤3min(90%, 20ºC)
Polarization time: >8h
Minimum flow rate: 5cm/s; 515 L/h
Drift: <3%/month
Measurement error: <±1 ppb
Air current: 50-80nA   Note: Maximum current 20-25 uA
Polarization voltage: 0.7V
Zero Oxygen: <5ppb(60min)
Calibration intervals: >60 days
Measured water temperature:0~60ºC
Scope of application
Applied to thermal power plants, power plant desalted water,.
boiler feed water etc places of trace oxygen content.


FAQ
Q: Are you trading company or manufacturer ?
A: We are factory.

Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock,
it is according to quantity.

Q: Do you provide samples ? is it free or extra ?
A: We can offer the sample, it is extra

Q: What is your terms of payment ?
A: 100% T/T in advance ,balance before shippment.

If you have another question, pls feel free to contact us as below:
Contact: Jori Liu
 
Mobile: +86 17507082182
 Ppb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen ElectrodePpb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen ElectrodePpb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen ElectrodePpb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen ElectrodePpb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen ElectrodePpb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen ElectrodePpb Online Dissolved Oxygen Sensor High Quality Dissolved Oxygen Electrode

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now