Industrial Online Mornitoring Zirconia Oxygen Analyzer (BQG-2118)
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | Support |
| Warranty: | 1year |
Gold Member Since 2014
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Year of Establishment
2007-05-23
Number of Employees
111
Find Similar Products
Basic Info.
- Model NO.
- BQG-2118
- Customized
- Non-Customized
- Portable
- Non Portable
- Certification
- FCC, CE
- Gas
- O2
- Type
- Electrochemical Gas Analyzer
- Item
- Zirconia Oxygen Analyzer
- Model
- Bqg-2118
- Heating-up Time
- Approx 20 Minutes
- Current Output
- 0-10mA DC or 4-20mA DC
- Transport Package
- PP Box, Paper Box, Seaworthy Box
- Specification
- CE, SGS, ISO
- Trademark
- BOQU
- Origin
- Shanghai, China
- HS Code
- 9027809900
- Production Capacity
- 9000piece/Month
Product Description
BQG-2118 Industrial online mornitoring Zirconia Oxygen Analyzer
BQG-2118 Industrial online mornitoring Zirconia Oxygen Analyzer is practical and reliable on-line automatic oxygen analyzer. Its measurement and display system consists of an oxygen detector (sensor) and a display instrument (transmitter). The detector is made of heat-resisting and anti-corrosion materials and can be directly inserted into flues for measurement of oxygen. The display instrument adopts single-chip control and can be used in combination with various electric unit combination instrument, general display recorder instruments and distributed control systems (DCS).
Zirconia oxygen analyzer is used for rapid and accurate on-line measurement and analysis of the oxygen contents in the flue gas produced by combustion equipments, such as boilers, furnaces and heaters, so as to realize control of low-oxygen combustion, energy saving and pollution abatement.
Features
1. The sensor is made of heat-resisting and anti-corrosion materials with high reliability.
2. With a special structural design, this analyzer doesn't need external air pump, and the reference air can realize convection by itself.
3. The sensor has a standard air interface, which enables calibration check on the site and provides convenient maintenance.
4. It adopts single-chip control and data processing with quick response, accurate measurement and stable performance.
Technical indexes
1. Measuring range: 0~20.6%
2. Accuracy: ≤ ± 2%FS
3. Temperature of flue gas measured: ≤ 600º C(low temperature type)
600~800º C(high temperature type)
4. Excess air coefficient of flue gas measured: 0.1-99
5. Response time: ≤ 3 seconds (90% response)
6. Current output: 0-10mADC or 4-20mADC
7. Power supply: 220V± 10% 50HZ± 5%
8. Working conditions: Ambient temperature: 0~50º C
Relative humidity: <85%
9. Heating-up time of the heater of zirconia detector: Approx 20 minutes