Benchtop Laboratory Digital Sodium Analysis, Monitor

Resolution: 0.01 Pna
Transport Package: PP Box, Paper Box, Seaworthy Box
Specification: SGS
Trademark: BOQU
Origin: Shanghai
Customization:

Contact Supplier

Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
DWS-51
HS Code
9027809900
Production Capacity
6000piece/Month

Product Description

DWS-51 Laboratory Sodium Meter

DWS-51 Sodium Ion Concentration Meter is designed for measuring the sodium ion content in aqueous solution, especially suitable for the quality monitoring of high-purity water in the power plants (such as steam, condensate water, boiler feed water, etc.). It can also be used for measuring the sodium ion concentration in the natural water and the industrial drainage in high education institutions, research institutes, petrochemical industry, microelectronics industry, etc.

Features
DWS-51 Sodium Ion Concentration Meter adopts the single-chip computer technology, featured by the simple and convenient operation as well as the intuitive and accurate digital display.
The instrument has the manual temperature compensation and the automatic temperature compensation functions(When it accesses to the temperature electrode, it enters the automatic temperature compensation and displays the current temperature; when it does not access to the temperature electrode, the instrument enters the manual temperature compensation and displays the manually set temperature value.) 
In addition to pNa value display, the instrument also has the function of sodium ion concentration [Na+] display function.The external shape of the instrument is compact and beautiful.


Technical Indexes
1.Measuring range:
                          a) PNa value: (0.00~9.00) pNa
                          b) Na+ concentration: 23g/L~0.023 μ g/L
                          c) mV value: -1800~1 800 mV
2. Resolution: 0.01 pNa
3. Intrinsic error of electronic units: ±0.02pNa ±1 unit
4. Intrinsic error of the instrument: ±0.05pNa
5. Calculation error in the conversion between PNa Value and [Na+] Concentration value: ± 0.3% (reading)
6. Instrument repeatability error: No more than ± 0.03pNa ± 1 unit
7. Temperature compensation range for measured solution: 5.0 ~ 50.0 ºC
8. Electronic unit stability: ± 0.02pNa/3h

Standard Configuration
One DWS-51 laboratory Sodium meter, One PNa electrode, One PNa reference electrode, One temperature electrode, one cable, one bracket.

Send your message to this supplier

*From:
*To:
avatar Miss Vera Yang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
111
Year of Establishment
2007-05-23